Search our site

Enter a keyword on the right to search our site.

PN380
DMX Interface

The PN380 allows the Prolojik network to provide specialist lighting control effects, in conjunction with DMX colour changing lighting

Prolojik control systems can be extended with the addition of a PN380 DMX controller which provides DMX colour changing control of lighting. The controller converts network commands from scene plates, touchscreens, switches, sensors or timed schedules to specialist and feature lighting.

DMX lighting is normally found in facades, reception areas, atriums and stages, so the controller can be installed locally or remotely depending on project requirements.


Specifications

Features
DMX Master
XLR5 and CAT 5/6 DMX connections
LonWorks Network Connection
Industry Standard DIN M36 form-factor

Networking
LonWorks™ network TP/FT-10 (Capacitor Decoupled)

Cabling & Connectors
Power input
DMX output
LonWorks™ interface

Dimensions
106 mm x 86 mm x 56 mm (LxWxH)

Fixings
Spring retractive DIN rail mounting clip
DIN EN50022

Safety
BS EN 62368

Conformity and Standards
Generic emission: EN 6100
Generic immunity: EN 6100
LonMark™ compliant

Environment
Storage
Temperature: -10ºc - +60ºc
Humidity: 0% - 90% non condensing

In Use
Temperature: 0ºc - +40ºc
Humidity: 10% - 90% non condensing

Power Input
Requires 9-35V AC or DC power supply

Output
DMX output
Connection: 5 pole XLR or CAT 5/6 connection
Screened 2 core cable as Belden 43906 - DMX512
cable or equivalent to be used.
Maximum total length 120m
Data cable must be isolated from mains
DMX driver addresses to be set by others